This standard is issued under the fixed designation D ; the 1 This test method is under the jurisdiction of ASTM Committee D04 on Road. D / DM Standard Test Method for Theoretical Maximum Specific Gravity and Density Standard + Redline PDF Bundle, 8, $, ADD TO CART . ASTM D pdf - Download as PDF File .pdf), Text File .txt) or read online.


Astm D 2041 Pdf

Author:LOREEN LINDLOFF
Language:English, French, German
Country:Netherlands
Genre:Business & Career
Pages:469
Published (Last):14.10.2015
ISBN:793-5-46022-692-3
ePub File Size:29.59 MB
PDF File Size:8.63 MB
Distribution:Free* [*Registration Required]
Downloads:48566
Uploaded by: AILEEN

ASTM D - 03 _rdiwndetukve - Download as PDF File .pdf), Text File .txt) or read online. ASTM D - Density of Bituminous paving Mixtures. ASTM D/Dm APPARATUS. 1. Containers (Clause ) a. Vacuum bowls (weighing in water) / Clause download ASTM Da Standard Test Method for Theoretical Maximum Specific Gravity and Density of Bituminous Paving Mixtures from SAI Global.

If there is any doubt without submerging the top of the flask. Measure and record as to whether the mix has absorbed water, proceed with this the temperature of the water in the flask. Remove the ther- procedure in order to determine if this correction is needed. The cover a flat tray with a nonabsorptive surface and place in front of a plate shall be the same one used during the calibration of the fan to remove surface moisture.

Standard Test Method for Theoretical Maximum Specific Gravity and Density of Asphalt Mixtures

Break agglomerations of flask. Wipe any moisture from the exterior of the container and mixture by hand. Stir the sample intermittently in such a way cover plate. Determine the mass of the flask, plate, and its that the aggregate particles are rolled over rather than simply contents completely filled with water. Designate this mass as E.

This process takes about 2 h. Take care to prevent the loss of particles of mixture. Calculation When Report where: The figures given Section A in Column 3 are the limits that should not be exceeded by the Single-operator precision 0.

Multilaboratory precision 0. When more than two results are being evaluated, the for Bowl Method only :B range given in Column 3 must be increased. Multiply the Single-operator precision 0.

A Basis of estimate: analysis of paired test results from to laboratories Example for three tests: 0. Additional guidance and background is given in Practice B Basis of estimate: 2 replicates, 7 materials, 20 laboratories. C ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

Users of this standard are expressly advised that determination of the validity of any such patent rights, and the risk of infringement of such rights, are entirely their own responsibility. This standard is subject to revision at any time by the responsible technical committee and must be reviewed every five years and if not revised, either reapproved or withdrawn.

Your comments are invited either for revision of this standard or for additional standards and should be addressed to ASTM International Headquarters.

Related Post: ASTM D PDF

Your comments will receive careful consideration at a meeting of the responsible technical committee, which you may attend. If you feel that your comments have not received a fair hearing you should make your views known to the ASTM Committee on Standards, at the address shown below.

Individual reprints single or multiple copies of this standard may be obtained by contacting ASTM at the above address or at phone , fax , or service astm. Class 7. Procedure can be connected directly to the vacuum source or be in the 9.

ASTMD

Cool the sample to room temperature. Calibration of Containers reduce the amount of water vapor entering the vacuum pump.

This device 9. To avoid damage. NOTE 4—If stripping of asphalt is a problem.

Place the cover 6. Accurate filling of the flask shall be ensured by the use of a mercury is the difference in the height of mercury. Place the E 1. The water bath sample and designate the net mass mass of sample only as A. This oven is needed when samples other than vacuum line. D — 03a pressure without visibly deforming. Sampling conforming to the requirements of Specification D It is to be volumetric lid on the bowl while under water.

Additional equal accuracy. Designate the of the container to attach the hose.

The hose connection in the flask should be laboratory prepared mixtures using oven-dry aggregate are covered with a small piece of fine wire mesh to minimize the tested. Designate this mass as B.

Do not 6. This device shall the loss of any fine material. This process takes about 2 h. The cover a flat tray with a nonabsorptive surface and place in front of a plate shall be the same one used during the calibration of the fan to remove surface moisture.

Astm d pdf

Slide the lid onto the bowl without Measure and record the temperature of the water in the bath. Take care to prevent the loss of particles of mixture. Repeat this procedure a second time by removing the lid and placing both Supplemental Procedure for Mixtures Containing lid.

Designate this mass as E. Determine the mass of the flask. Break agglomerations of flask. Designate the mass under water of the bowl and sample as C. It is not necessary to by the bituminous film. To determine if this has oc- mass varies by more than 1.

ASTM D

Measure and record as to whether the mix has absorbed water. If the during the vacuum procedure. Place the Remove the bowl with tested.

Report where: Wipe any moisture from the exterior of the container and mixture by hand. Measure Porous Aggregate and record the temperature of the water in the bowl. When Both the temperature and mass are measured at this time. Apparatus 6.

You might also like: ASTM D - 10 EBOOK DOWNLOAD

NOTE 1—The transparent cover allows observation of the release of air bubbles. If underwater measurements will be taken, then the balance shall be equipped with a suitable suspension apparatus and holder to permit weighing the sample while suspended from the center of the scale.

To avoid damage, the manometer or gage itself is not to be situated on top of the vessel but adjacent to it. NOTE 2—Residual pressure in the vacuum vessel in millimetres of mercury is the difference in the height of mercury.

This device can be connected directly to the vacuum source or be in the vacuum line close to the source. NOTE 3—The vacuum leg of a residual pressure manometer occasion- ally acquires one or more air bubbles that introduce error into the residual pressure reading.Repeat this procedure a second time by removing the lid and placing both Wipe any moisture from the exterior of the container and cover plate.

Documents Similar To ASTM D pdf

To determine if this has oc- mass varies by more than 1. It is the responsibility of the user of this standard to establish appropriate safety, health, and environmental practices and determine the applicability of regulatory limitations prior to use. Wipe any moisture from the exterior of the container and mixture by hand. ASTM International takes no position respecting the validity of any patent rights asserted in connection with any item mentioned in this standard.

Ther- separation of the mixture is needed so that the particles of the mometers shall conform to the requirements of Specification fine aggregate portion are not larger than about 6 mm. The mass under water is recorded, and the specimen is taken out of the water, blotted quickly with a damp cloth towel, and weighed in air. Designate this mass as B.